Daily operation and maintenance of water-cooled air conditioner

Please read this code carefully before operation, otherwise it will cause malfunction or damage:

1. Operation of the controller: When the temperature is high, the indoor needs to cool down, press the “cooling” button directly, and the delay will start for one minute. This is a normal phenomenon. After one minute, the unit enters the “cooling” operation state;

2. Cleaning of the bottom basin: The controller is equipped with a “cleaning” button, which is used to clean the bottom basin and change the water. The bottom basin must be cleaned once a day to ensure that the sent air is fresh and clean;

3. The cold medium of Correlai energy-saving environmental protection air conditioner is water, so the water source should be in the open state for a long time, and it is required to have a water pressure of more than 1.5Kg per square meter. When the unit is running, if there is no cooling effect, check whether there is water shortage. If there is no water, the indicator light is on, further check whether the faucet is closed, whether the water pressure is insufficient, whether the inlet valve and the water pump and the water level sensor are damaged;

4. When the temperature is low (winter) or the humidity is high (spring, rainy weather), you can press the “send air” button to directly send fresh air into the room;

5. The unit is operated for more than half a year, and the evaporator needs to be cleaned once. The water pressure during cleaning should not be too high to avoid damaging the evaporator;

6. Stop by pressing the “stop” button;

7. When winter comes, it will be deactivated for a long time. To prevent freezing damage to the body and mosquito breeding, close the tap water and press the “Cleaning” button to clear the water.

Inspective maintenance:

1), according to the operation of the equipment and customer needs, carry out various routine inspections in a planned manner;

2) In order to ensure more efficient operation of the evaporative cooling unit, please use this product under the following conditions:

a) Ambient temperature: 18 ° C - 45 ° C

b) ambient relative humidity: ≤ 85%;

c) Atmospheric pressure: 86Kpa-106Kpa;

d) The water supply needs to be softened, the water supply temperature is ≤ 45 ° C, and the water supply pressure is 0.15-0.6 Mpa;

e) the voltage deviation does not exceed ±10% of the rated voltage;

f) The ambient air quality should meet the GB 3096 level 3 (including the third level) standard;

g) Non-corrosive environment.

3) This product is flammable. Please do not approach the fire during transportation, installation and operation.

4) Please pay attention to whether the inlet pipe and the drain pipe are connected well before use, otherwise the leakage may cause damage to other equipment or products.

5) In order to ensure the best effect of the machine, it should be ensured that there are doors or windows that are open enough. If there are not enough open doors or windows, you can load the blinds or install other mechanical ventilation equipment.

6) During the operation of the machine, do not disassemble the engine parts such as the evaporator and the top cover. If the machine needs to be repaired or maintained, the power should be cut off first, otherwise the machine may be damaged or human casualties may occur.

7) Check the condition of the motor during installation. Do not use fuses or other wires with incorrect capacity.

8) In order to ensure the cooling effect, the filter may be considered in areas where the air is more turbid.

9) For places with strict requirements on humidity and temperature, consult a professional for guidance.

10) If there is any abnormality in the operation of this product, please inform the company or dealer for repair.

Preventive maintenance:

1), pre-season maintenance. Before the start of the season, check the perimeter of the unit and the air inlet for obstructions.

2), the unit is used for maintenance. Pay attention to the cleaning of the chassis. Press the “Cleaning” button on the control panel every day to change the water to prevent bacteria and odors from occurring.

3), unit cycle maintenance. The unit is operated for 1-2 months. If the curtain is wet, the filter is clogged or the site is too dirty, it should be cleaned in time to avoid malfunction or affect the operation of the machine.

4), the end of the season maintenance. In order to prevent freezing damage to the body and mosquito breeding, when the water is turned off for a long time, turn off the tap water, then press the cleaning button to clear the water and cut off the power.

5), the inside of the unit is clean. If the unit is running for a long time, in order to ensure the cooling effect, the machine must be cleaned once every 1 or 2 months. Please refer to the instruction manual for detailed disassembly cleaning methods.

Anti-magnetic: Because the ceramic bearing is non-magnetic and does not absorb dust, it can reduce the early peeling of the bearing, noise, etc., and can be used in demagnetization equipment. Precision instruments and other fields.
 Insulation Due to the high resistance of ceramic bearings, it can be protected from arc damage and can be used in various electrical equipment requiring insulation.
 self-lubricating characteristics Because of the unique oil-free self-lubricating properties of ceramic bearing materials, in the ultra-high vacuum environment, it can overcome the problem that ordinary bearings can not achieve lubrication.
High-speed ceramic bearing has the advantages of cold resistance, small elasticity, high pressure resistance, poor thermal conductivity, light weight and small friction coefficient. It can be applied to high-speed spindles of 12000 rpm/-75000 rpm and other high speeds. In precision equipment;

Zirconia Ceramic Shaft

Zirconia Ceramic Shaft,Resistance Zirconia Ceramic Rod,Zirconia Ceramic Piston Shaft,Ceramic Shaft

SHENZHEN HARD PRECISION CERAMIC CO.,LTD , http://www.hardcm.com